Flash Sale: 10% OFFEnds in
Daikin High Static DuctedDucted (High Static)

Daikin High Static Ducted 22.0 kW

Model: FDA250A

Daikin FDA250A ducted (high static)
On sale
Supply pricewas £7,699.00 now £6,929.10

Installed from was £14,449.99 now £13,009.99 at 0% VAT

Delivery included with installation

Daikin manufacturer's warrantyAsk us for the warranty terms that apply to your system.

Why buy me

  • High static ducted, 200 to 250 Pa
  • All indoor units supplied as standard with air filter
  • Replacement Technology: can reuse suitable existing refrigerant pipework
  • Madoka wired touch screen controller BRC1H52W7 (white) included in the price
  • Up to 250 Pa external static pressure
  • Auto balancing airflow / ESP on commissioning
Cools 22.0 kW Heats 24.0 kW

Buy the unit with installation for 0% VAT

Buy the unit and the installation together and the whole job is 0% VAT in a home. Delivery is included with installation.

Product only

was £7,699.00 now £6,929.10

£8,314.92 inc. 20% VAT

Just the unit. No installation included.

Buying the unit on its own returns soon

Installation package

Unit + professional installation, 0% VAT

£14,949.99

One room, fitted by Refresh Cooling in the North West, with the power cable to the outdoor unit and no service plan.

Equipment and materials inc. 20% VAT£12,838.80
Installation inc. 20% VAT£5,101.19
Government 0% VAT saving−£2,990.00
Total you pay£14,949.99
Choose options & book installation

Our builder works out the right size for your own room, so the price may change with the room.

What’s included in your installation

  • Installation by F-Gas and REFCOM certified engineers (F-Gas is the legal qualification for handling the cooling gas)
  • Indoor unit fitted to the wall and the outdoor unit on a bracket or ground base
  • Pipes and cables between the units, hidden in a colour-matched cover (trunking)
  • A drain pipe for the water the indoor unit collects (condensate)
  • A power cable of its own to the outdoor unit, when you ask us to fit it
  • Pipes pressure tested and emptied of air before the cooling gas goes in
  • Switching on and checking the system (commissioning), and showing you the controls
  • Packaging and waste taken away, and any marks around the work repaired
  • Daikin manufacturer's warranty on the equipment

Not included

  • Scaffolding, or lifts and special ladders for hard-to-reach places
  • Asbestos removal
  • Building work beyond repairing marks around the installation

We check the job for free before we fit it (a survey), in case the pipe route or access is not the usual.

Room size

The same unit in other sizes. A bigger room needs more kW (cooling power). We size your actual room when we quote.

The FDA250A is a 22.0 kW Daikin ducted (high static) system from the High Static Ducted range. A high static ducted unit for long duct runs and large commercial spaces, with the airflow balanced automatically when it is commissioned.

  • Bluevolution technology
  • Replacement Technology: can reuse suitable existing refrigerant pipework
  • Madoka wired touch screen controller BRC1H52W7 (white) included in the price
  • Madoka Plus BRC1KPD51W enhanced wired controller available as an option
  • Wi-Fi control with the Daikin Onecta app, with the BRP069C82 Wi-Fi adaptor available as an option
  • All indoor units supplied as standard with air filter
  • Up to 250 Pa external static pressure
  • Auto balancing airflow / ESP on commissioning
  • External static pressure 250 Pa high / 62 Pa nominal
  • Optional controllers: Madoka white/silver/black (BRC1H52W7/S7/K7), Madoka Plus white/black (BRC1KPD51W/K), wireless remote BRC4C65
  • Integration options: KNX interface KLIC-DI_V2, Modbus PCB EKMBPP1A + UK.FB2, unit/group adaptor PCB KRP4A53 + UK.FB2 (remote on/off, status, temperature setting), RTD-10 (duty rotation, lead/lag, heating interlock), RTD-20 (energy control)
  • Remote room temperature sensor KRCS01-6B (wired) or SB.K.RSS_FDA wireless sensor and receiver for FDA200 and 250A
  • FDA200-250A requires separate single-phase power supply
Need advice?
Call 01253 366054

Or ask for a specialist to call you back.

Request a specialist callback

Expert Installation Across the North West

Local experts

Domestic installations across Blackpool & Fylde Coast, Preston, Leyland and surrounding Lancashire areas.

Regional hubs

Serving major North West cities including Manchester & Liverpool with dedicated rapid-response teams.

UK-wide reach

Our own installation teams cover the North West, with the North East and Midlands coming soon. Outside the North West we can give you an estimate for your own F-Gas certified installer.

Map of Great Britain showing where Refresh Cooling installsInstallation is available now in the North West of England. The North East, the Midlands and nationwide supply are coming soon.North West (installing now)North East (coming soon)Midlands (coming soon)

Where we install

  • Installing now: North West
  • Coming soon: North East, Midlands, nationwide supply
  • Head office: Poulton-le-Fylde, Lancashire
Based in Poulton-le-Fylde, Serving the Nation